Login | Register
产品中心
Home > Products > Thermal insulation aluminum tiles > Flame retardant thermal insulation aluminum tile

Flame retardant thermal insulation aluminum tile

    Flame retardant thermal insulation aluminum tile

    Flame retardant thermal insulation aluminum tiles are designed to provide superior fire safety, energy efficiency, and long-lasting durability for modern construction projects. Made from high-quality aluminum alloys with advanced flame-retardant insulating cores, these tiles effectively resist fire, reduce heat transfer, and maintain structural integrity under extreme conditions. Their lightweight design, corrosion resistance, and easy installation make them ideal for residential, commercial, and industrial roofing or cladding applications. Combining safety, thermal performance, and aesthetic...
  • Share:
  • Contact us Inquiry
  • WhatsApp:8615833457666

Flame Retardant Thermal Insulation Aluminum Tile: Safe and Energy-Efficient Roofing Solution

1. Introduction

In modern construction, balancing fire safety, thermal insulation, and durability is critical. Flame retardant Thermal insulation aluminum tiles are engineered to meet these demands, offering superior fire resistance, thermal performance, and long-term structural integrity.

These tiles are ideal for residential, commercial, and industrial buildings, providing benefits such as reduced energy consumption, enhanced safety, and aesthetic versatility. The lightweight aluminum structure combined with advanced insulating cores ensures both ease of installation and long-term reliability.


2. Product Overview

Flame retardant aluminum tiles consist of a high-quality aluminum alloy surface, a flame-retardant insulating core, and a durable backing layer. This combination provides thermal efficiency, fire protection, and corrosion resistance, making the product suitable for various roofing and cladding applications.

2.1 Key Specifications

ParameterSpecification
Base MaterialAluminum alloy (3003 / 5052 / 6061)
Sheet Thickness0.5–1.5 mm
Insulation MaterialPU, PIR, EPS, or Rock Wool (flame retardant)
Thermal Conductivity≤ 0.025 W/(m·K)
Fire ResistanceClass B1/B2 (flame retardant)
Surface CoatingPVDF, PE, or nano self-cleaning coating
Weight3–5 kg/m²
Lifespan25–30 years
Color OptionsSilver, Grey, Bronze, Red, Custom Colors
ApplicationsResidential, commercial, industrial roofs and walls

2.2 Product Highlights

  1. Flame Retardant: Reduces fire risk while maintaining structural integrity.

  2. Superior Thermal Insulation: Minimizes heat transfer to save energy.

  3. Lightweight Design: Lowers structural load and simplifies installation.

  4. Corrosion Resistance: Protects against UV, moisture, and pollutants.

  5. Quick Installation: Interlocking design accelerates assembly.

  6. Low Maintenance: Durable coatings reduce cleaning and upkeep requirements.

  7. Aesthetic Flexibility: Wide range of colors and finishes for modern architecture.


Flame retardant thermal insulation aluminum tile


3. Structural Details

Understanding the structure of flame retardant aluminum tiles is essential for installation, performance, and durability.

3.1 Layer Composition

  • Top Aluminum Layer: Provides strength, corrosion resistance, and UV protection.

  • Flame-Retardant Insulation Core: PU, PIR, EPS, or Rock Wool, offering thermal efficiency and fire safety.

  • Backing Layer: Ensures dimensional stability and moisture resistance.

3.2 Mechanical Properties

PropertyValue
Tensile Strength≥ 150 MPa
Flexural Strength≥ 120 MPa
Surface Hardness≥ 45 HV
Thermal Expansion Coefficient22–24 ×10⁻⁶ /°C
Water Absorption≤ 0.5%
Acoustic Insulation25–35 dB
Fire ResistanceClass B1/B2

3.3 Advantages of Layered Construction

  • Thermal Efficiency: Reduces indoor temperature fluctuations.

  • Fire Safety: Flame-retardant core slows fire propagation.

  • Corrosion Resistance: Top coating protects against environmental damage.

  • Lightweight Strength: Supports long-span applications with minimal structural load.


4. User Guide

Proper usage ensures maximum performance, safety, and longevity.

4.1 Recommended Applications

  • Roofs and walls of residential homes, villas, and townhouses

  • Commercial buildings such as offices, warehouses, and shopping centers

  • Industrial facilities requiring fire-resistant and energy-efficient materials

4.2 Operating Precautions

  • Avoid direct contact with open flames beyond rated exposure.

  • Do not walk on the tiles without proper protection to prevent dents.

  • Inspect tiles for damage or coating defects before installation.

  • Ensure adequate ventilation under roofing systems to prevent condensation.


5. Installation Steps

Correct installation is critical for fire protection, thermal efficiency, and structural performance.

5.1 Preparation

  • Confirm roof or wall frame is level, stable, and load-bearing.

  • Check tiles for defects, scratches, or coating damage.

  • Collect necessary tools: drill, level, measuring tape, stainless steel screws, rubber washers, sealant, gloves, and safety harness.

5.2 Installation Process

  1. Begin installation from the lowest edge, working upwards.

  2. Align tiles accurately for seamless interlocking.

  3. Fasten tiles with stainless steel screws and rubber washers to prevent leaks.

  4. Apply high-temperature flame-retardant sealant at overlaps and joints.

  5. Avoid stepping directly on installed tiles; use protective planks.

  6. Inspect installation for alignment, fastening, and coating integrity.

5.3 Safety During Installation

  • Always wear helmets, gloves, and anti-slip footwear.

  • Use safety harnesses when working on sloped surfaces.

  • Avoid installation during strong wind or heavy rain.

  • Handle tiles carefully to prevent scratches, dents, or coating damage.


6. Cleaning Methods

Proper cleaning maintains thermal performance, fire resistance, and aesthetic appeal.

6.1 Cleaning Guidelines

  • Use low-pressure water and mild detergent.

  • Avoid abrasive brushes, acids, or strong chemicals.

  • Clean more frequently in coastal or industrial areas to prevent salt or pollutant buildup.

6.2 Cleaning Frequency

ConditionRecommended Cleaning
Residential areasEvery 12 months
Industrial areasEvery 6–9 months
Coastal areasEvery 3–6 months

7. Upgrade Solutions

Upgrading your aluminum tile system can enhance fire safety, thermal efficiency, and durability.

7.1 Enhanced Insulation

  • Replace standard PU or EPS cores with high-performance PIR or Rock Wool cores.

  • Increases fire resistance rating and thermal efficiency.

7.2 Coating Upgrades

  • Apply PVDF or nano self-cleaning coatings for enhanced UV and corrosion protection.

  • Improves lifespan and aesthetic retention.

7.3 Integration with Solar or Ventilation Systems

  • Install photovoltaic panels on top of flame-retardant tiles.

  • Incorporate ventilation channels beneath tiles to reduce heat accumulation and enhance efficiency.


8. Maintenance Procedures

Routine maintenance ensures long-lasting performance and safety.

8.1 Inspection Schedule

TaskFrequencyPurpose
Visual InspectionEvery 6 monthsDetect loose screws, surface scratches, or dents
Sealant CheckEvery 2 yearsEnsure fireproof and waterproof joints
Coating AssessmentEvery 3 yearsCheck for fading, peeling, or corrosion
Structural AssessmentEvery 5 yearsInspect roof/wall frame and tile alignment

8.2 Repair Procedures

  • Loose Screws or Joints: Retighten and reseal.

  • Surface Scratches: Use touch-up coatings compatible with high-temperature and fire-resistant tiles.

  • Dents or Warping: Replace affected tiles to maintain performance.

  • Coating Damage: Apply protective coating to exposed areas immediately.


9. Common Issues and Solutions

IssueCauseSolution
Water leakageLoose fasteners or insufficient overlapRetighten screws, reseal joints
Fading or discolorationUV exposureApply UV-resistant coating
Noise during rainLoose tiles or improper fasteningReinforce fasteners or add insulation layers
WarpingHeat stress or heavy impactReplace affected tiles
CorrosionSurface scratches or coating damageApply protective coating

10. Storage and Handling Guidelines

Proper storage preserves fire resistance and structural integrity.

10.1 Storage Guidelines

  • Store tiles in a dry, ventilated area, away from moisture.

  • Keep tiles flat and supported to prevent bending or deformation.

  • Outdoor storage requires UV-resistant, waterproof covers.

  • Avoid stacking heavy objects on top of tiles.

10.2 Handling Guidelines

  • Wear gloves to prevent scratches and protect hands.

  • Use soft padding when moving or stacking tiles.

  • Avoid dragging tiles across hard surfaces.

  • Lift large panels with mechanical aids or straps to prevent deformation.


11. Applications

11.1 Residential Applications

  • Modern homes, villas, townhouses

  • Roofs and walls requiring fire-resistant insulation

  • Energy-efficient, eco-friendly buildings

11.2 Commercial and Industrial Applications

  • Office buildings, warehouses, factories

  • Shopping centers, hospitals, and schools

  • Facilities requiring fire safety compliance and energy efficiency

11.3 Architectural Integration

  • Compatible with glass facades, metal panels, and modular roofing systems

  • Supports modern design aesthetics while maintaining fire and thermal performance


12. Advantages Over Traditional Materials

FeatureFlame Retardant Aluminum TilesClay TilesConcrete Tiles
Weight3–5 kg/m²30–40 kg/m²40–50 kg/m²
Fire ResistanceClass B1/B2MediumHigh
Thermal InsulationHighModerateLow
Corrosion ResistanceExcellentLowModerate
MaintenanceLowMediumHigh
Installation SpeedFastSlowModerate
Lifespan25–30 years15–20 years20–25 years
Recyclability100%PartialLimited

13. Conclusion

Flame retardant thermal insulation aluminum tiles offer a modern, safe, and energy-efficient solution for roofing and cladding. Their lightweight design, flame-retardant insulation core, and corrosion-resistant coatings ensure long-term performance with minimal maintenance.

Following proper installation, cleaning, and maintenance procedures ensures maximum fire safety, thermal efficiency, and structural durability, making these tiles an ideal choice for residential, commercial, and industrial construction projects.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

Contact Information

Indiana Office

Contact Person: Wang Ye

Tel: +86 158 33457666

Email: 944713874@qq.com

Address: South side of Yuxin Highway, Dongxian Village, Yahongqiao Town, Yutian County, Tangshan City, Hebei Province

Search

F.png I.png Y.png ins.png T.png

This website uses cookies to ensure you get the best experience on our website.

Accept Reject